Electric wire For aircraft and tanks 22759-1C

Short Description:

Temperature Range: Flexible- 40°C to+ 125°C

Temperature at Conductor: Max. UL: + 125°C

Bending Radius: Approx. 5 x cable ø


Product Detail

Product Tags

Application:

These cables have excellent resistance to abrasion, deformation, cut- through and chemical attack. This wire is widely used in appliances, transformers, electrical heating, motors, ballast, lighting and cooking equipment.

photobank (5)
photobank (7)

 Suitable for use as Appliance Wiring Material (AWM), coil leads and as Class B IEEE 120°C Class Motor Leads. Economical replacement for silicone rubber/ glass braid insulated wire and cable.

Technical Data:

Standard: UL - Std. 758. Complies to CSA No. 22.2 210 and 127

Nominal Voltage: 300V

Test Voltage (Spark Test)

AWG 22 and 20 = 5kV

AWG 18 to 10 = 6kV ≥ AWG 8 = 7.5kV

Temperature Range: Flexible- 40°C to +125°C

Temperature at Conductor: Max. UL : +125°C

Bending Radius: Approx. 5 x cable ø

Cable Construction:

Annealed plain or tinned stranded copper conductor.

XLPE insulation according to UL- Std. UL758- 2010, UL1581- 2009

Properties:

XLPE self- extinguishing and flame retardant, test method to FT 2.

Sound sales network:

The company's sales network focuses on the Pearl River Delta and the Yangtze River Delta and radiates to the whole country.

We directly serve more than 30 large and medium- sized cities in China, and a large number of professional dealers provide professional support and services for customers all over the country.

The company has close partners in Hong Kong, Thailand and the United States to provide products and services for our global customers.

The products cover Europe, America, Australia, Asia and other regions.

Outline:

PRODCUT1

Ground vehicles with low voltage electric system

primary cable TXL

Marking: NO MARKING

model

size

AWG

Conductor structure

(branch/mm)

Conductor resistance 20℃

(Ω/Km)

Conductor diameter(mm)

Insulation thickness (mm)

overall diameter (mm)

average value

Min value

average value

tolerance

3266

10

105/0.254

3.54

3.00

0.50

0.33

4.00

±0.15

12

65/0.254

5.64

2.36

0.50

0.33

3.40

±0.15

14

41/0.254

8.96

1.88

0.50

0.33

2.90

±0.15

14

19/0.374

8.96

1.88

0.50

0.33

2.90

±0.15

14

1/1.63

8.78

1.63

0.50

0.33

2.63

±0.15

16

26/0.254

14.60

1.50

0.40

0.33

2.30

±0.1

 

19/0.3

14.60

1.51

0.40

0.33

2.31

±0.1

18

16/0.254

23.20

1.18

0.40

0.33

2.00

±0.1

 

41/0.16

23.20

1.18

0.40

0.33

2.00

±0.1

 

1/1.02

22.20

1.02

0.40

0.33

1.82

±0.1

 

34/0.18

23.20

1.21

0.40

0.33

2.01

±0.1

 

7/0.39

23.20

1.17

0.40

0.33

2.00

±0.1

 

19/0.235

23.20

1.18

0.40

0.33

2.00

±0.1

20

21/0.18

36.70

0.95

0.40

0.33

1.75

±0.1

 

19/0.19

36.70

0.95

0.40

0.33

1.75

±0.1

 

7/0.30

36.70

0.90

0.40

0.33

1.70

±0.1

22

17/0.16

59.40

0.76

0.40

0.33

1.56

±0.1

 

7/0.254

59.40

0.76

0.40

0.33

1.56

±0.1

 

65/0.08

59.40

0.74

0.40

0.33

1.54

±0.1

24

11/0.16

94.20

0.61

0.40

0.33

1.41

±0.1

 

19/0.120

94.20

0.60

0.40

0.33

1.40

±0.1

 

1/0.51

89.30

0.51

0.40

0.33

1.31

±0.1

 

7/0.20

94.20

0.61

0.40

0.33

1.41

±0.1

26

7/0.16

150.00

0.48

0.40

0.33

1.28

±0.1

26

1/0.40

143.00

0.40

0.40

0.33

1.20

±0.1

26

19/0.10

150.00

0.50

0.40

0.33

1.30

±0.1

28

7/0.127

239.00

0.38

0.40

0.33

1.18

±0.1

28

1/0.32

227.00

0.32

0.40

0.33

1.12

±0.1

30

7/0.10

381.00

0.30

0.40

0.33

1.10

±0.10

30

1/0.254

361.00

.254

0.40

0.33

1.05

±0.10

 

Structure description:

Conductor structure: Tinned / bare conductor

Insulation material: polyethylene insulation XLPE

Internal wiring of equipment, polyethylene insulated wire with conductor temperature not exceeding 125 ℃

Rated temperature: 125 ℃ rated voltage: 300V

packing

size

Packing method- Ft/roll

 

image18.jpeg 

 

 

10AWG

□ 200Ft

■ 500Ft

□ 1000Ft

□ 2000Ft

12~16AWG

□ 200Ft

□ 500Ft

■ 1000Ft

□ 2000Ft

18~30AWG

□ 200Ft

□ 500Ft

□ 1000Ft

■ 2000Ft

Also can customized 

Mark on wire: E211048 AWM STYLE 3266 NO. AWG 125℃ 300V XLPE QIFURUI c AWM I A 125℃ 300V FT2 -LF-

OR: E211048 AWM STYLE 3266 NO. AWG 125℃ 300V VW- 1 XLPE QIFURUI c AWM I A 125℃ 300V FT2 -LF-


  • Previous:
  • Next:

  • Related Products